Perkins, 3.152, Technical features, Fault diagnosis,BERCO CR3006,BERCO CR962A,CATERPILLAR 6S7880,CATERPILLAR 6Y1244,CATERPILLAR 7H0463,CATERPILLAR 7T8987,ITM Q01030A0M01,VPI VCR3006V,LIEBHERR,Excavator,R901

How to clean the integral closed breather system

1000 series » How to clean the integral closed breather system

Caution: Do not use excessive force to remove the hose (A4) from the breather outlet pipe.

Note: The procedure below refers only to the closed breather shown in (A).

  1. Release the hose clip and carefully remove the hose from the breather outlet.
  2. Remove the rocker cover.
  3. Caution: Ensure that the lever does not damage the cover.

  4. Release the fasteners and carefully remove the breather cover from the breather body. A suitable lever may be necessary to release the cover from the body of the breather. Ensure that the lever does not damage the cover. Discard the joint (A5).
  5. Caution: Do not clean the breather valve or the gauze filter. The breather valve (A1) and the gauze (A3) must be renewed every 4000 hours.

  6. Release the clips (A2) from the clip retainers (A7) and push the breather valve out of the breather cover.Discard the breather valve.
  7. Remove and discard the gauze.
  8. Warning! Do not allow compressed air to contact your skin. If compressed air enters your skin, obtain medical help immediately.

  9. Wash the body of the breather, the cover, the baffle plates (A6) and the breather pipe, every 2000 hours of operation. Use an approved kerosene cleaning fluid and dry them with compressed air at low pressure.
  10. Ensure that the holes at the bottom of the baffle plates in the breather body are not restricted. If necessary, clean the holes.

To assemble

  1. Fit the baffle plates into the grooves in the breather body.
  2. Renew and fit the gauze filter into the breather body.
  3. Renew and fit the new valve into the breather cover. Ensure that the clips are engaged correctly.
  4. Note: The breather valve is renewed every 4000 hours.

  5. Renew the joint, which is fitted dry. Put the cover and valve assembly into position on the breather body. Loosely fit the fasteners. Tighten the fasteners gradually and evenly to 3 Nm (2.2 lbf ft) 0.3 kgf m.
  6. Caution: Do not use excessive force to fit the hose to the breather outlet pipe.

  7. Check that there is no restriction in the breather pipe or the breather hose. Fit the breather hose to the cover and tighten the clip.
Inapoi Seria motor Perkins 1000 series
În ultimii 50 de ani majoritatea lucrărilor de excavare în rocă si demolări au fost realizate utilizând ciocane hidraulice clasice. Tot în acesti 50 de ani producătorii de echipamente pentru demolări si-au concentrat eforturile în vederea cresterii eficientei si productivitătii cioca
mai multe detalii ...
ITM Q01030A0M01, Technical features, R901, CATERPILLAR 6S7880, 3.152, VPI VCR3006V, LIEBHERR, Fault diagnosis, CATERPILLAR 7H0463, Perkins, BERCO CR962A, CATERPILLAR 6Y1244, BERCO CR3006, Excavator, CATERPILLAR 7T8987
Utilajele cele mai "respectate" atunci când vorbim de pregatirea unor suprafete mari de teren, precum taluzarea marginilor unei autostrazi sau pistele noi de aeroport sunt grederele. Probabil ca este un semn nu prea bun pentru piata noastra ca numarul de astfel de utilaje vândute este foarte mic &
mai multe detalii ...
Fault diagnosis, BERCO CR962A, Technical features, VPI VCR3006V, 3.152, CATERPILLAR 7H0463, ITM Q01030A0M01, Perkins, Excavator, CATERPILLAR 6Y1244, R901, CATERPILLAR 6S7880, CATERPILLAR 7T8987, BERCO CR3006, LIEBHERR

Sediu : 700045 Iasi, Strada Sfantul Lazar nr. 27, Kapital Invest Building -  etajul 2
Depozit :
700382 Iasi,Str. Aurel Vlaicu 88
600343 Bacau,Str. Letea 32
062202 Bucuresti, Str. Preciziei 32
2059 Chisinau, Str. Petricani 19/4

Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025

Telefon Romania:

+40 743 122 261
office@commatech.ro