,HANOMAG,60E,BERCO LH1137,HYUNDAI 81E8-2004,HYUNDAI 81EH-10050,INGERSOLL RAND 57407314,ITM PV9544B0M00,ITM PV9544B0Y00,LIEBHERR 10004545,LIEBHERR 10009662,LIEBHERR 5605656,LIEBHERR 5607652,LIEBHERR 580096100,SENNEBOGEN 3424031903,VERMEER 1239870011,VPI V81E8-2004V,HYUNDAI,Excavator,R350LC

Coolant specification

1000 series » Coolant specification

The quality of the coolant which is used can have a great effect on the efficiency and life of the cooling system. The recommendations indicated below can help to maintain a good cooling system and to protect it against frost and/or corrosion.

If the correct procedures are not used, Perkins cannot be held responsible for damage caused by frost or corrosion.

Caution: An antifreeze which contains the correct inhibitor must be used at all times to prevent damage to the engine by corrosion, because of the use of aluminium in the coolant circuit:

  • If frost protection is not necessary, it is still extremely important to use an approved antifreeze mixture because this gives a protection against corrosion and also raises the boiling point of the coolant.
  • If the approved antifreeze mixture is not available, add a correct mixture of corrosion inhibitor to the water. If the correct inhibitor is not used, the engine will be damaged by corrosion. If there is doubt about the corrosion inhibitor to be used, It is recommended that you consult the Perkins Service Department, Peterborough.

Note: If combustion gases are released into the coolant circuit, the coolant must be renewed after repair of the fault.

The antifreeze which is recommended for this engine is the latest POWERPART Antifreeze, see page 53. This antifreeze contains the correct corrosion inhibitor which is especially suitable for this engine. If it is possible, use clean soft water in the coolant. The quality of the antifreeze coolant must be checked at least once a year, for example, at the beginning of the cold period. The coolant must be renewed every two years.

Caution: The antifreeze mixture must consist of equal quantities of antifreeze and water. The corrosion inhibitor in the antifreeze will be diluted if a concentration of less than 50% of antifreeze is used. Concentrations of more than 50% of antifreeze may have an adverse effect on the performance of the coolant.


Inapoi Seria motor Perkins 1000 series
Constructorul american Case este deja unul dintre partenerii de încredere ai armatei americane. Fabrica CNH din Wichita, Kansas va livra peste 3.000 de unităţi, contractul pe termen lung presupunând producerea a 1.900 de încărcătoare multifuncţionale pe pneuri şi până la 1.500 de mini&ic
mai multe detalii ...
HYUNDAI 81EH-10050, VPI V81E8-2004V, , LIEBHERR 580096100, LIEBHERR 5605656, INGERSOLL RAND 57407314, ITM PV9544B0M00, VERMEER 1239870011, HANOMAG, LIEBHERR 10009662, R350LC, 60E, SENNEBOGEN 3424031903, LIEBHERR 10004545, Excavator, LIEBHERR 5607652, HYUNDAI, BERCO LH1137, HYUNDAI 81E8-2004, ITM PV9544B0Y00
Noul excavator pe pneuri Komatsu PW148-8 - puternic si versatil O altă noutate pe care producătorul japonez Komatsu o va prezenta este ultimul model de excavator pe pneuri, PW148-8, cu un design compact, cu spatele scurt, pentru a putea fi folosit cu usurintă în santiere cu spatiu limitat de manevră sau pe st
mai multe detalii ...
VPI V81E8-2004V, HANOMAG, Excavator, HYUNDAI 81EH-10050, HYUNDAI 81E8-2004, ITM PV9544B0Y00, , INGERSOLL RAND 57407314, LIEBHERR 580096100, VERMEER 1239870011, HYUNDAI, SENNEBOGEN 3424031903, LIEBHERR 5607652, LIEBHERR 10009662, LIEBHERR 5605656, ITM PV9544B0M00, LIEBHERR 10004545, BERCO LH1137, R350LC, 60E

Sediu : 700045 Iasi, Strada Sfantul Lazar nr. 27, Kapital Invest Building -  etajul 2
Depozit :
700382 Iasi,Str. Aurel Vlaicu 88
600343 Bacau,Str. Letea 32
062202 Bucuresti, Str. Preciziei 32
2059 Chisinau, Str. Petricani 19/4

Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025

Telefon Romania:

+40 743 122 261
office@commatech.ro