How to clean the gauze strainer of the fuel lift pump

1000 series » How to clean the gauze strainer of the fuel lift pump

  1. Release the fastener (A2) and remove the cover and the joint (A3) from the top of the fuel lift pump (A4). Remove the gauze strainer (A1). On some turbocharged engines, it will be necessary to remove the small heat shield which is fitted above the pump.
  2. Wash carefully all of the sediment from the lift pump body.
  3. Clean the gauze strainer, the joint and the cover.
  4. Assemble the lift pump. Use a good joint and ensure that the lift pump body and the cover are fitted together correctly because leakage at this point will let air into the fuel system. Fit the heat shield, if one is fitted.
  5. Eliminate the air from the fuel system through the filter vent plug.
Back Perkins engine series 1000 series
more details ...
Excavator, ITM Z14043A0N0500V, BERCO CR4834/500, POCLAIN-CASE POCLAIN W2042351, R210LC-7, O-&-K-TEREX 1778092, UP TO 0055, LIEBHERR, Senila, VPI VCR4834/500, R921B, HYUNDAI, HYUNDAI 81E6-28010, Excavator
more details ...
UP TO 0055, R210LC-7, BERCO CR4834/500, HYUNDAI, Senila, POCLAIN-CASE POCLAIN W2042351, VPI VCR4834/500, O-&-K-TEREX 1778092, Excavator, R921B, ITM Z14043A0N0500V, LIEBHERR, HYUNDAI 81E6-28010, Excavator

Headquarters : 700045 Iasi, 27 Sfantul Lazar Street, Kapital Invest Building -  2nd Floor
Warehouse :
700382 Iasi,88 Aurel Vlaicu Street
600343 Bacau, 32 Letea Street
062202 Bucuresti, 32 Preciziei Street
2059 Chisinau, 19/4 Petricani Street

Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025

Phone Romania:

+40 743 122 261
office@commatech.ro