There are two methods to eliminate air from the fuel system according to the type of fuel injection pump fitted:
The standard method is used where the fuel injection pump has vent screws (A1/2) and (B1).
The self-vent method is used where the fuel injection pump has a self-vent feature. These pumps have a vent pipe (C1) fitted between a connection in the top of the pump and the atomiser leak-off pipe. Vent screws are not fitted to these pumps.
If air enters the fuel system, it must be eliminated before the engine can be started.
Air can enter the system if:
If air enters the fuel system, it must be eliminated before the engine can be started.
In order to eliminate air from the fuel system, proceed as follows:
Caution: Do not allow fuel from the engine to contaminate the engine compartment. Put a drip tray under the engine and discard old fuel in accordance with local instructions.

Note: If the cam for the fuel lift pump is at the point of maximum lift, it will not be possible to operate the priming lever. In this situation, the crankshaft must be rotated one turn.
Caution: Use a spanner on the flats (A1) of the fuelled starting aid to prevent its movement when the union nut (A2) is loosened and tightened.


Fuel injection pumps used on some Lucas and all Stanadyne fuel injection pumps will automatically remove air from the fuel system. Vent screws are not fitted to these pumps.
Caution: Although these fuel injection pumps will eliminate air automatically, use the procedure that follows to remove air from the fuel system if the system is drained or a major component is removed: Ensure that fuel has been added to the tank or that the leakage has been corrected.
Note: If the cam for the fuel lift pump is at the point of maximum cam lift, it will not be possible to operate the priming lever. In this situation, the crankshaft must be rotated one turn.
Caution: Use a spanner on the flats (A1) of the fuelled starting aid to prevent its movement when the union nut (A2) is loosened and tightened.
Cautions:
If the engine runs correctly for a short time and then stops or runs roughly, check for air in the fuel system. If there is air in the fuel system, there is probably a leakage in the low-pressure system.

| Назад | Perkins двигатель серии 1000 series |
Центральный офис : 700045 Яссы, Ул. Сфынтул Лазэр 27, Здание Капитал Инвест – 2 этаж
Склад :
700382 Яссы, Ул. Аурел Влайку 88
600343 Бакэу, Ул. Летя 32
062202 Bucuresti, 32 Preciziei Street
2059 Кишинев, Ул. Петрикань 19/4
Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025
Телефон Румыния:
+40 743 122 261
office@commatech.ro