How to renew the lubricating oil

3.152 Series » How to renew the lubricating oil

  1. Operate the engine until it is warm
  2. Stop the engine, remove the sump drain plug (A1) and its washer and drain the lubricating oil from the sump. Ensure that the washer is not damaged. Fit the drain plug and a new washer and tighten the plug to34Nm (25lbfft) 3,5kgf m.
  3. Fill the sump to the mark on the dipstick (B1) with new and clean lubricating oil of an approved grade, see “Lubrificating oil specification??? board.

How to renew the canister of the lubricating oil filter

  1. Put a tray under the filter to retain spilt lubricating oil.
  2. Remove the filter canister with a strap wrench or similar tool. Ensure that the adaptor (A1) is secure in the filter head. Then discard the canister.
  3. Clean the filter head.
  4. Add clean engine lubricating oil to the new canister. Allow the oil enough time to pass through the filter element.
  5. Lubricate the top of the canister seal with clean engine lubricating oil.
  6. Fit the new canister and tighten it by hand only. Do not use a strap wrench.
  7. Ensure that there is lubricating oil in the sump. On turbocharged engines, ensure that the engine will not start and operate the starter motor until oil pressure is obtained. To ensure that the engine will not start, either put the manual stop control in the "stop" position or disconnect the electrical stop control of the fuel injection pump. Oil pressure is indicated when the warning light is extinguished or by a reading on the gauge.
  8. Operate the engine and check for leakage from the filter. When the engine has cooled, check the oil level on the dipstick and put more oil into the sump, if necessary.

Caution: The canister contains a valve and special tube to ensure that lubricating oil does not drain from the filter. Therefore, ensure that the correct Perkins POWERPART canister is used.

Назад Perkins двигатель серии 3.152
,больше подробностей ...
PMI 960007, VPI VCR1447V, 4.236, DRESSER-FURUKAWA 3375447R1, Excavators, LALTESI 96819, Operation instructions, JCB 447/10702, Perkins, SUMITOMO-LINKBELT 98A1925C, Technical features, LIEBHERR, BERCO CR1447, R941, ITM Q14050A0M01, LIEBHERR 5209467, FAI 820810010, 101-379
,больше подробностей ...
Technical features, Excavators, ITM Q14050A0M01, Perkins, VPI VCR1447V, LALTESI 96819, PMI 960007, LIEBHERR, SUMITOMO-LINKBELT 98A1925C, BERCO CR1447, JCB 447/10702, 4.236, LIEBHERR 5209467, DRESSER-FURUKAWA 3375447R1, Operation instructions, FAI 820810010, R941, 101-379

Центральный офис : 700045 Яссы, Ул. Сфынтул Лазэр 27, Здание Капитал Инвест – 2 этаж
Склад :
700382 Яссы, Ул. Аурел Влайку 88
600343 Бакэу, Ул. Летя 32
062202 Bucuresti, 32 Preciziei Street
2059 Кишинев, Ул. Петрикань 19/4

Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025

Телефон Румыния:

+40 743 122 261
office@commatech.ro